Product nameIndustrial pH meter
ModelHP-480
Measuring range0 pH to 14 pH: 0.01 pH resolution.
Temperature 0¡æ to 100¡æ: 1¡æ resolution (selectable display).
Transmission
output
4 mA to 20 mA DC: input/output isolated type
Maximum load resistance: 900 ¦¸
Transmission
output range
Free
Repeatability and
linearity
¡À0.05 pH, ¡À0.08 mA (for transmission output range of 0 pH to 14 pH)
Contact outputOutputs: 2 points
Alarm contact output (R1 and R2)
??Contact type: relay contact, SPDT (1c)
??Contact rating: 240 V AC, 3 A and 30 V DC, 3 A (resistance load)
??Contact function: selectable from upper/lower limit operation (ON/OFF control), alarm, and maintenance.
Calibration functionTwo-point automatic calibration or manual calibration.
Two-point automatic calibration: with automatic validation of the electrode characteristics.
??Types of standard solution: pH 2, pH 4, pH 7, pH 9 and pH 10 (JIS)
??Combination of standard solutions: pH 7 and one of the others
??Manual calibration: Freely selectable, but the difference should be over 2 pH.
Temperature calibration (one point).
Transmission
output hold feature
  • Previous value hold
  • Optional value hold
  • Continuous
    Selectable from the above (However, only the previous value hold is available in the maintenance mode).
Self-diagnosis
function
  • Calibration function
    Asymmetry potential error, sensitivity error, response speed error and standard solution error.
  • Electrode self-diagnosis
    Temperature sensor short-circuit and temperature sensor disconnection.
  • Outside of the measuring range.
  • Converter error.
Temperature
compensation
element

Selectable from compensation ON (350¦¸ (25¡æ), 500¦¸ (25¡æ),1 k¦¸ (0¡æ)6.8 k¦¸ (25¡æ)
and 10 k¦¸ (25¡æ)) and compensation OFF.

Temperature-
compensated
range
0¡æ to 100¡æ
Ambient
temperature
?5¡æ to 45¡æ
Relative humidity20% to 85% (without dew condensation)
Storage
temperature
?25¡æ to 65¡æ
Power supplyRated voltage 100 V AC to 240 V AC, 50 Hz/60 Hz, 10 VA (max.)
StructureIndoor-use panel installation type
??Panel case: ABS, Terminal: PBT
Panel: water proof structure
Protective structurePanel: IP65 (IEC60529, JIS C0920)
Rear case: IP20, Terminal: IP00
Class II device (IEC61010-1)
Pollution level 2 (IEC61010-1)
Conforming
standards
CE MarkingEMC Directive: EN61326-1
Low Voltage Directive: EN61010-1
RoHS Directive: EN50581
Immunity (Industrial electromagnetic environment)
Noise increase ¡À0.2 pH or less
FCC RuleFCC Part15
External
dimensions
48 (W)  ¡Á 96 (H)  ¡Á 115 (D) mm
Case depth: approx. 105 mm
MassApprox. 400 g

ÁôÑÔÖJѯ

ÈçÄúÓÐÈκÎÒÉÎÊ£¬ÇëÔÚ´ËÁôÏÂÏêϸÐèÇó»òÎÊÌ⣬ÎÒÃǽ«½ß³ÏÄú·þÎñ¡£

* ß@Щ™Úλžé±ØÌîí—Ä¿¡£

¸ü¶àÍÆ¼ö

0040N-10D
0040N-10D

ISFET pH electrode

Glass Electrode 1076A-10C
Glass Electrode 1076A-10C

For measurement of low-conductivity water and non-aqueous solvents.

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

LAQUA DO210
LAQUA DO210

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DO220
LAQUA DO220

Handheld Dissolved Oxygen/Temperature Meter

LAQUA DS-72
LAQUA DS-72

Benchtop Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA EC1100
LAQUA EC1100

Benchtop Water Quality Meters

LAQUA EC210
LAQUA EC210

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA EC220
LAQUA EC220

Handheld Conductivity/Resistivity/Salinity/Total Dissolved Solids/Temperature Meter

LAQUA F-72
LAQUA F-72

Benchtop pH/ORP/Ion/Temperature Meter

LAQUA F-73
LAQUA F-73

Benchtop pH/ORP/Ion/Temperature Meter

LAQUA F-74
LAQUA F-74

Benchtop pH/ORP/Ion/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA PC1100
LAQUA PC1100

Benchtop Water Quality Meters

LAQUA PC210
LAQUA PC210

Handheld pH/ORP/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA PC220
LAQUA PC220

Handheld pH/ORP/Conductivity/Resistivity/Total Dissolved Solids/Salinity/Temperature Meter

LAQUA PD2000
LAQUA PD2000

Benchtop pH/ORP/Ion/DO/BOD/Temperature Meter

LAQUA PD210
LAQUA PD210

Handheld pH/ORP/Dissolved Oxygen/Temperature Meter

LAQUA PD220
LAQUA PD220

Handheld pH/ORP/Dissolved Oxygen/Temperature Meter

LAQUA PH1100
LAQUA PH1100

Benchtop Water Quality Meters

LAQUA PH1200
LAQUA PH1200

Benchtop Water Quality Meters

LAQUA PH1300
LAQUA PH1300

Benchtop Water Quality Meters

0040N-10D
0040N-10D

ISFET pH electrode

514-05
514-05

0.5% NaCl Standard Solution

514-22
514-22

1.41 mS/cm Conductivity Standard Solution

514-23
514-23

12.9 mS/cm Conductivity Standard Solution

514-50
514-50

5.0% NaCl Standard Solution

Corporate