Model | CS-600F | ||
---|---|---|---|
Measurement principle | Absorption spectroscopic method | ||
Calculation principle | Temperature compensation type multivariate analysis | ||
Measurement target | NH3/H2O2/H2O (reperesentative specification) * Please contact 蓝鲸体育直播 regarding other chemicals. | ||
Measurement range | NH3锛0.00锝1.20尘补蝉蝉%銆丠2O2锛0.00锝5.50尘补蝉蝉%銆 H2翱锛93.3锝100.0尘补蝉蝉% | ||
Repeatability | NH3锛毬0.05尘补蝉蝉%銆丠2O2锛毬10尘补蝉蝉%銆丠2翱锛毬1.0尘补蝉蝉% Chemical temperature: Within 卤1鈩/1 hour | ||
Sample solution temperature | 20銆80鈩 | ||
Measurement cycle | Approx. 3 seconds | ||
LCD display | (1) Measured value (%) (2) Concentration alarm (HH/H/L/LL) (3) Error code (EXXX) (4) Chemical temperature (掳C) (5) Serial/parallel communication status (P/S) (6) The times of background correction failure (CXXX) | ||
Key input | (1) Concentration alarm setting (HH/H/L/LL) (2) Concentration value shift (3) Background correction (4) Hot water correction (5) Temperature dependent concentration shift | ||
Parallel input | Input voltage of 12 V to 30 V DC by insulating with photo coupler (1) Parallel concentration alarm output (On/Off) (2) Switching chemical solution for measurement (including background correction) (3) Hot water correction | ||
Parallel output | Transistor output (NPN open collector) by insulating with photo coupler Maximum current when powered ON: 5 mA DC (no internal protective resistance) Maximum voltage when powered OFF: 30 V DC (1) Concentration alarm (ON at HH/H/L/LL alarm) (2) Monitor error (OFF at error) (3) Measuring (ON at measurement) (4) Chemical solution type for measurement (5) Echo to hot water correction input (6) Warning (ON at occurred) (7) Background correction status 8) Hot water correction status | ||
Serial input | RS-232C (1) Request for readout of measurement data (2) Select chemical solution type to be measured (3) Hot water correction | ||
Serial output | RS-232C | ||
Analog output | 4 mA to 20 mA In case of monitor error occurs, measurement is stopped or invalid chemical range is selected, the signal output is fixed at 1.5 mA. The load resistor must be 500 惟 maximum. | ||
Chemical solution temperature input | Terminal block inlet (terminal screw M3) Platinum resistance temperature sensor: Pt100 (Three-conductor type, Class A) *Temperature sensor is not included. | ||
Air (for operation and purge) | Connection port: 4 mm O.D. quick joint, Pressure: 0.2 MPa 卤0.02 Mpa | ||
Power source | 100锝230V AC锛圫ingle-Phase锛夈50/60Hz | ||
Power consumption | Approx. 85 VA (transient electric current at the time of the start is excluded) | ||
Weight | (Monitor) Approx. 3.6 kg (Lamp unit) Approx. 2.8 kg (Sample cell) Approx. 1.2 kg | ||
Ambient temperature | (Monitor, Lamp unit) 20掳C to 30掳C (Sample cell, Optical fiber) 20掳C to 35掳C (Sudden temperature change should be avoided, within 卤1掳C/1 hour) | ||
Ambient humidity | (Monitor, Lamp unit, Sample cell) 40% to 70% (Should be no dew condensation) | ||
Slanting angle at installation | (Monitor, Lamp unit) within 卤1掳 | ||
Optical fiber | Length: 5 m, minimum bend radius: R 150 mm |