蓝鲸体育直播

Hyperspectral PoliSpectra® H116

Hyperspectral Imaging Spectrometer Applications

蓝鲸体育直播 has developed a unique hyperspectral imaging spectrometer with an integrated scientific CMOS camera (12-16 bit) featuring HDR (95dB Dynamic Range and 1.7e- noise) and 95% Q.E peak efficiency:

PoliSpectra庐 H116 features broad UV-NIR coverage in one acquisition (185-1050 nm) combined with the highest spectral resolution (<1 nm).

The elegant all-concentric design combines high spatial and spectral resolution using a type-I holographic diffraction grating. This system is used as a line-scanning instrument (push-broom) that collects full spectral data simultaneously, across the input slit height at 188 frames per second (or higher with AOI/binning).

For OEM hyperspectral and multispectral applications

  • Remote Sensing (Aerial - drone/uas/uav or aircraft鈥)
  • Quality Control Inspection / Optical metrology in Semiconductors
  • DNA sequencing / Capillary Electrophoresis / PCR
  • Process Monitoring by Reflectometry, Emission, Raman, Fluorescence鈥
  • Microscopy (Mapping, Complete custom solutions)
  • Advanced Machine Vision / Industrial camera
  • Recycling (Sorting and quality control in recycling plants)
  • Food & Beverage Inspection

 

Alternatively, we offer H135, a more compact product with less spectral resolution and coverage

*Available in select countries.

You can email OEM Technical Sales at: OEM.US(at)horiba.com or contact OEM at: +1.732.494.8660 Ext. 7733

小械谐屑械薪褌: Scientific
袩芯写褉邪蟹写械谢械薪懈械: Mini-Spectrometers and Scientific Cameras for OEMs
袩褉芯懈蟹胁芯写懈褌械谢褜: 蓝鲸体育直播 Scientific
  • Superb imaging quality
  • Frame rates as fast as 188 fr/s 
  • High spectral and spatial resolution at F/2.3
  • High throughput combined with low stray light performance
  • 2D Scientific CMOS with high quantum efficiency and low noise
  • Broad wavelength coverage from 185 nm to 1050 nm
  • Stable and robust

 

Thermal stability study cycling from -20潞C to 50潞C

 

Scientific CMOS Back-Illuminated Sensor Quantum Efficiency

 

Hyperspectral Imaging Distortions: Keystone and Smile

 

OEM Spectrometer Selection Guide

 

You can email OEM Technical Sales at: OEM.US(at)horiba.com or contact OEM at: +1.732.494.8660 Ext. 7733

 

 

General Spectrometer Specifications*
Spectral Coverage185鈥1050 nm
Tunable at factory between these ranges: 185-920 nm and 280-1050 nm
Spectral Resolution 1.25 nm typical (22 渭m slit width) and up, depending on the slit size
Spatial Resolution50 碌m typical
Spectral Dispersion34.6 nm/mm; 0.38 nm/pixel
Focal Length116 mm
F/#F/2.3
Smile and Keystone1.5 pixel (typical)
Stray Light**< 0.1% (typical)
Wavelength Accuracy0.1 nm (using multi-area wavelength calibration)
SoftwareLabVIEW鈩 acquisition software for initial evaluation (DLLs provided for software integration)

 

Specifications for Scientific Back-Illuminated CMOS Image Sensor with High Speed Electronics
Detector ModelsCMOS BI sensor with electronic rolling shutter (All the parameters are specified at normal room temperature of 25潞 C unless otherwise noted)
Sensor Format***2048 x 512
CMOS Pixel Size11 碌m x 11 碌m
CMOS Height5.6 mm
CMOS QEThe peak QE is 77% at 250 nm and 95% at 560 nm (refer to graphs below)
Thermoelectric CoolingUncooled
Frame Rate94 fps (HDR mode), 188 fps (STD mode) on 2D sCMOS sensor
Full Well80 ke炉 typical (HDR mode)
Readout Noise1.6 e炉 typical, 2.0 e炉 maximum
Digitization16-bit (HDR mode), 12-bit (High Sensitivity mode
Dynamic Range (HDR mode)93.9 dB typical in HDR mode
Non-linearity
(measured on each system)
< 1.8% (maximum) in HDR mode  <0.9% (maximum) at high gain
CommunicationUSB 3
Environmental ConditionsOperating temperature 15掳 C to 40掳C  ambient; 
Relative humidity <70% (non-condensing); Storage temperature -25掳 C to 45掳 C
Power requirements
AC/DC Power Supply (provided)
90-264 VAC, 47鈥63 Hz


* Specifications, form factor, and spectrometer cover subject to change without notice. No LabVIEW license is needed to run our acquisition software.
** Stray light using BP Filter: Baseline light level, outside the band, divided by BP peak (unsaturated) value.
*** 

 

Scientific CMOS Back-Illuminated Sensor Quantum Efficiency

Mechanical Drawings

 

 

You can email OEM Technical Sales at: OEM.US(at)horiba.com or contact OEM at: +1.732.494.8660 Ext. 7733

袟邪锌褉芯褋懈褌褜 懈薪褎芯褉屑邪褑懈褞

校 胁邪褋 械褋褌褜 胁芯锌褉芯褋褘 懈谢懈 锌芯卸械谢邪薪懈褟? 袠褋锌芯谢褜蟹褍泄褌械 褝褌褍 褎芯褉屑褍, 褔褌芯斜褘 褋胁褟蟹邪褌褜褋褟 褋 薪邪褕懈屑懈 褋锌械褑懈邪谢懈褋褌邪屑懈.