蓝鲸体育直播

Calibration Laboratory for Exhaust Gas Measurement

蓝鲸体育直播 Europe GmbH with its laboratory for exhaust gas measurement technology in Oberursel, near Frankfurt, carries out calibrations of measuring instruments and sensors for the measurands and measuring ranges specified during accreditation. The DAkkS/DKD calibration certificates issued in accordance with the accreditation are proof of traceability to national standards, such as those required by the DIN EN ISO 9001 and DIN EN ISO/IEC 17025 family of standards.

On a regular basis, the German Accreditation Body (Deutsche Akkreditierungsstelle GmbH (DAkkS)) confirms that the calibration laboratory of 蓝鲸体育直播 Europe GmbH with the laboratory for exhaust gas measurement technology in Oberursel (Germany) has the competence according to DIN EN ISO/IEC 17025:2018 to perform accredited calibrations both in the permanent laboratory and on-site at the customer's location.

Downloads:


  •  

鈻 Contact us for more information

On-site calibration

Calibration objectRange ProcedureSmallest measurement uncertainty that can be specified *)
Pressure
Absolute pressure gauge0,6鈥1,1&苍产蝉辫;产补谤Gas pressure mediumDKD-R 6.1卤0,68&苍产蝉辫;尘产补谤
Overpressure gauge0鈥100&苍产蝉辫;尘产补谤Gas pressure mediumDKD-R 6.10鈥70&苍产蝉辫;尘产补谤:&苍产蝉辫;卤0,06&苍产蝉辫;尘产补谤
>70鈥100&苍产蝉辫;尘产补谤: 卤0,18 mbar
Temperature
Resistance thermometers and direct reading thermometers with resistance sensors (Pt100, Pt1000 etc.)-20鈥+155&苍产蝉辫;掳颁Comparison calibration with resistance thermometer in block calibratorsDKD-R 5.1-20鈥&濒迟;0&苍产蝉辫;掳颁:&苍产蝉辫;卤0,45&苍产蝉辫;碍
0鈥+100&苍产蝉辫;掳颁:&苍产蝉辫;卤0,22&苍产蝉辫;碍
&驳迟;+100鈥+155&苍产蝉辫;掳颁:&苍产蝉辫;卤0,45&苍产蝉辫;碍

*) Please note that the smallest measurement uncertainty that can be specified cannot necessarily be realized on every calibration object and may be less favorable in the specific application.

Permanent laboratory

Calibration objectRange ProcedureSmallest measurement uncertainty that can be specified *)
Pressure
Absolute pressure gauge0,6鈥1,1&苍产蝉辫;产补谤Gas pressure mediumDKD-R 6.1卤0,68&苍产蝉辫;尘产补谤
Overpressure gauge0鈥100&苍产蝉辫;尘产补谤Gas pressure mediumDKD-R 6.10鈥70&苍产蝉辫;尘产补谤:&苍产蝉辫;卤0,06&苍产蝉辫;尘产补谤
>70鈥100&苍产蝉辫;尘产补谤: 卤0,18 mbar
Number of particles concentration
Condensation particle counter (CPC)200鈥10000&苍产蝉辫;1/肠尘鲁Particle size 23 to 100 nmISO 27891卤8,0 %
Particle Number Concentration to determine the Particle Number Concentration Reduction Factor (PCRF)笔颁搁贵&苍产蝉辫;150鈥3000VPR Particle size 30 to 100nm PCRFUNECE R83卤8,77 %
Relative humidity
Comparative measurement in humidity generator
Air temperature: 23 掳C
10鈥90 % RHComparison calibration with resistance thermometer in block calibratorsDKD-R 5.81,7 % RH
Temperature
Resistance thermometers and direct reading thermometers with resistance sensors (Pt100, Pt1000 etc.)-20鈥+155&苍产蝉辫;掳颁Comparison calibration with resistance thermometer in block calibratorsDKD-R 5.1-20鈥&濒迟;0&苍产蝉辫;掳颁:&苍产蝉辫;卤0,45&苍产蝉辫;碍
0鈥+100&苍产蝉辫;掳颁:&苍产蝉辫;卤0,22&苍产蝉辫;碍
&驳迟;+100鈥+155&苍产蝉辫;掳颁:&苍产蝉辫;卤0,45&苍产蝉辫;碍
Resistance thermometers and direct reading thermometers with resistance sensors (Pt100, Pt1000 etc.)-0鈥+60&苍产蝉辫;掳颁Comparison calibration with resistance thermometer in humidity generatorDKD-R 5.10,39 K

*) Please note that the smallest measurement uncertainty that can be specified cannot necessarily be realized on every calibration object and may be less favorable in the specific application.

In the realm of measurement and control technology, achieving the highest possible precision is crucial. Calibration laboratories play a vital role in ensuring the reliability and reproducibility of measurements by calibrating various sensors and measuring instruments. Metrology, the science of measurement, defines calibration as an activity that first establishes a relationship between standard quantity values and their measurement uncertainties and the corresponding indications. This relationship is then used to derive accurate measurement results from these indications.

The calibration of test and measurement systems is essential for maintaining the functionality and accuracy of measuring equipment. In a calibration laboratory, all necessary instruments, machines, and software are organized within an optimized workspace. This environment is meticulously controlled, with stringent standards for temperature and humidity to ensure precise and standardized measurements.

Regular calibration is necessary, varying based on the type and design of the equipment. Additionally, any measuring equipment that has undergone repair or maintenance must be recalibrated to confirm its accuracy. The calibration laboratory, therefore, serves as the central hub where all components and expertise come together to ensure the reliability and precision of measurement equipment.

Contact / Inquiry 

Connect with our experts 鈥 we're eager to hear from you! Don't hesitate to reach out by using the form provided below.

袟邪锌褉芯褋懈褌褜 懈薪褎芯褉屑邪褑懈褞

校 胁邪褋 械褋褌褜 胁芯锌褉芯褋褘 懈谢懈 锌芯卸械谢邪薪懈褟? 袠褋锌芯谢褜蟹褍泄褌械 褝褌褍 褎芯褉屑褍, 褔褌芯斜褘 褋胁褟蟹邪褌褜褋褟 褋 薪邪褕懈屑懈 褋锌械褑懈邪谢懈褋褌邪屑懈.

* 协褌懈 锌芯谢褟 芯斜褟蟹邪褌械谢褜薪褘 写谢褟 蟹邪锌芯谢薪械薪懈褟.

Related Products

MEXA-ONE
MEXA-ONE

Motor Exhaust Gas Analyzer

OBS-ONE GS Unit
OBS-ONE GS Unit

On-board Emissions Measurement System

SPCS-ONE
SPCS-ONE

Solid Particle Counting System

Corporate