HD-480

???????(4-Wire Transmission), ???? ?)

??? ??????? HD-480? ???????? ?? ??? ?? ??? ???? ??? ???? ??? ???? ?????.
??? ????? ??? ??? ?? ??? ????, ??? ?? ??? ? ????.

- ?? ??(?? ??) : 0 ~ 20 mg/L
- ?? : 0 ~ 200%
- ?? : 0 ~ 40℃

Division: Process Water
Manufacturing Company: 蓝鲸体育直播 Advanced Techno Co., Ltd.
  • Exchanging the sensor is a one-touch operation
    The sensor is disposable, and can be exchanged with the touch of a key.
    There is no need for work requiring long experience or expertise, such as exchanging the membrane or refilling the internal fluid, as generally required by other sensors until now.
  • Two types of span correction
    You can choose from two types of span correction: the commonly used saturated fluid correction, and the plain and simple atmospheric correction.
  • Salt adjustment function
    A function which automatically corrects the data based on the salt concentration of the measurement sample has been included.
    This means it can make precise measurements in both freshwater and seawater.
  • Uses lead-free solder
    To reduce the burden on the environment, lead-free solder has been used to mount the components on the printed circuit board.
 Product name Dissolved oxygen meter
Model  HD-480
Measurement methodGalvanic cell method
Measuring range
  • Dissolved oxygen 0 mg/L to 20 mg/L, 0.01 mg/L resolution
  • Saturation 0% to 200%, 1% resolution
  • Temperature 0℃ to 40℃, 0.1℃ resolution
RepeatabilityWithin ±0.5% of the full scale (by equivalent input)
LinearityWithin ±0.5% of the full scale (by equivalent input)
Transmission
output
  • 4 mA to 20 mA DC, input/output isolated type
  • Max. load resistance: 900 Ω
  • Transmission output range: Freely settable within the measuring range
Contact outputOutputs: 2 points
Alarm contact output (R1 and R2)
?Contact type: relay contact, SPDT (1c)
?Contact rating: 240 V AC, 3 A and 30 V DC, 3 A (resistance load)
?Contact function: Selectable from “Upper limit operation”, “lower limit operation”
???(ON/OFF control), “anomaly alarm”, “during maintenance”, and “temperature”
Calibration function
  • Air calibration and solution calibration
  • Salinity compensation (0.0% to 5.0%)
  • Temperature calibration (two points)
Transmission output hold featureSelectable from previous value hold, optional value hold or continuous (however,only the previous value hold is available in the maintenance mode)
Self-diagnosis function
  • Calibration failure: Zero error and sensitivity error
  • Sensor diagnosis: Short-circuit or disconnection of temperature sensor
  • Measuring range error
  • Product error
Temperature-compensated range0℃ to 40℃
Ambient temperature?5℃ to 45℃
Relative humidity20% to 85% (without dew condensation)
Storage temperature?25℃ to 65℃
Power supplyRated voltage 100 V to 240 V AC, 50/60 Hz, 10 VA (max.)
StructureIndoor-use panel installation type
??Panel case: ABS, Terminal: PBT
Panel: IP65 dust and water proof structure
Protective structurePanel: IP65 (IEC60529, JIS C0920)
Rear case: IP20, Terminal:IP00
Class II device (IEC61010-1)
Pollution level 2 (IEC61010-1)
Compatible
standards
CE markingEMC?:EN61326-1
? ??Class A, Industrial electromagnetic environment
Safety :EN61010-1
RoHS ?:EN50581
??? 9. Industrial monitoring and control instruments
FCC rulesPart15 Class A
External dimensions48 (W) mm × 96 (H) mm × 115 (D) mm
Case depth: approx. 105 mm
MassApprox. 400 g
Compatible sensorsProbeDP-100Operating temperature: 0℃ to 45℃

Sensor

5400, 5405

 

?? ??

蓝鲸体育直播??? ??? ??? ????, ??? ??? ??? ??? ??????.

* ? ?????????.

Corporate