蓝鲸体育直播

Mini CCT Plus

Mini Raman Spectrometer

Raman CCD spectrometer with high sensitivity and dynamic range for OEM Raman hand-held applications.

  • High throughput (f/3.1)
  • Three Raman laser ranges: 532nm and 785nm
  • Ultra-miniaturization with CCD USB 2.0 electronics
  • 7000:1 dynamic range
  • SMA or permanent fiber-optic connection
  • VIS- or NIR-optimized back-illuminated CCD
  • CCT optical layout (Crossed-Czerny-Turner)

 Available for US OEM customers only

Segment: Scientific
Manufacturing Company: 蓝鲸体育直播 Scientific

Feature

Benefits for Spectroscopy

Raman range with 785 nm

 210 to 2700 cm鈥1 coverage

High dynamic range

7000:1 with low readout-noise of 35 e

Back-illuminated linear CCD

QE=77% at 600nm;55% at 850nm with    VIS-optimized (NIR-optimized option: yields 75% QE at 850 nm)

USB 2.0 high and full-speed

Standard connection interfaces to PCs with 100% data integrity

Windowsacquisition software and LabVIEW鈩 VIs and DLLs available

Software to integrate MINI-CCT+ as an OEM component

No moving parts or shutter

Excellent reliability for OEM integration


Available for US OEM customers only

Spectral coverage

With 532 nm laser:210 to 3500 cm鈥1
With 660 nm laser:400 to 3150 cm鈥1
With 785 nm laser:210 to 2700 cm鈥1

Numerical aperture

F/3.1

Stray light rejection
Typical (Maximum)

0.1% (0.2%)
(measured with bandpass filter 780BP10)

CCD Detector & Typical Q.E.

Back-illuminated CCD with low etaloning in NIR
55% peak QE at 850nm(VIS optimized)

Detector height
Fiber-optic option

300渭m CCD height standard (1000渭m optional)
200 or 300渭m dia.,1m long fiber optic (for 1mm tall CCD, RTS bundle is offered)

Thermoelectric stabilization

None. Dark current and CCD-pattern noise must be subtracted. User must shutter in optical path. QE shifts slightly with temperature.

Spectral resolution
Pixel resolution
Slit (factory configuration)

785nm configuration;25渭m slit; 2048 pixels; 8鈥12cm鈥1 resolution; 0.19nm/pixel (configuration with 300渭m tall CCD)
Available slits: 12-25-37-50-62-75-100-125-150-200渭m (contact us for other gratings)

Improved CCD full well
Raw non linearity
Factory corrected non linearity

>250Ke- (sensitivity mode)
<1% (sensitivity mode)

< 0.4% (sensitivity mode)

Typical dynamic range

7000:1 in sensitivity mode
 

Readout speed

8.6ms (500kHz mode); 116 spectra/s with 0 exposure time (Multi-Acq mode)
Max: 4.5 ms (Ultra mode); 223 spectra/s with 0 exposure time (Multi-Acq mode)

Typical Dark current

1 count/ms at 20掳C (room temp.); typical offset = 1000 counts

Typical readout noise

35 e- (Max= 45e-) in sensitivity mode (4 e/count)

A/D converter

16 bit, 500 kHz (pixel rate); optional 2 MHz VIS-CCD

Typical dynamic range

7,000:1 in sensitivity mode

Weight

1.8 lb (0.82 kg)

Gain selection

4 e-/count and 8 e-/count

Dimensions (H脳  W脳D)

4鈥 脳 2.71鈥 脳 1.49鈥 (101.6 mm 脳 68.8 mm 脳 37.8 mm)

* Specifications, Form Factor and Spectrometer Covers are subject to change without notice.

Acquisition software included (LabVIEW鈩 2011 only)

  • VIs and top-level code are provided for customer customizations
  • Access to data with raw CCD linearity and corrected linearity done at factory for each CCD chip
  • CCD settings and dark-subtract
  • On-board or software averaging
  • Scale selection between pixel, wavelength, and wavenumber
  • On-board spectral calibration
  • Linearity correction on/off
  • save function to Excel or text 铿乴e

No LabVIEW鈩 license is needed to run our acquisition software. LabVIEW鈩 license ver. 2011 required to edit our code. No code customization supported in price.

鞝滍拡 氍胳潣

蓝鲸体育直播鞝滍拡鞚 鞛愳劯頃 鞝曤炒毳 鞗愴晿鞁滊┐, 鞎勲灅鞚 鞏戩嫕鞐 雮挫毄鞚 鞛呺牓鞚 攵韮侂摐毽诫媹雼.

* 電 頃勳垬鞛呺牓頃鞛呺媹雼.

Related products

1000M 鞁滊Μ歃
1000M 鞁滊Μ歃

鞛レ磮鞝愱卑毽 攵勱磻瓿

Gemini 180
Gemini 180

Double monochromator

iHR320
iHR320

欷戩磮鞝 旮胳澊 鞚措歆 攵勱磻旮

TRIAX 鞁滊Μ歃
TRIAX 鞁滊Μ歃

Short Focal Length Triple Grating Imaging Spectrographs

Corporate